Neonatal medical equipment

Neonatal medical equipment is specially designed to provide advanced care for premature or ill newborns in neonatal intensive care units (NICUs). These devices play a crucial role in supporting the health and survival of vulnerable infants during their early stages of life.

Infant Incubator

Infant incubator is a kind of medical equipment which works by "convection thermal regulation" and utilizes computer technology to implement servo control of the temperature inside the incubator. The servo control system is able to automatically adjust the temperature, humidity and other parameters in the incubator through sensors according to the actual needs of newborns, ensuring that the environment is always in the best state.

component

It mainly consists of crib, temperature controller, incubator chassis, blue light irradiation light box and so on.

temperature controller

Equipped with high-precision temperature sensor for real-time monitoring and regulating the temperature inside the box. Servo control mode: automatic adjustment according to newborn's skin temperature or preset ambient temperature.

Crib

The main area used to house a newborn baby, usually designed as a soft, secure, adjustable structure. Some of the beds can be tilted to facilitate nursing operations or special medical treatments by healthcare workers.

Blue light irradiation light box (optional)

Equipped in some incubators for the treatment of neonatal jaundice. Emits a specific wavelength of blue light to help break down bilirubin in the baby's body and reduce the symptoms of jaundice.

Transparent cover

provides a closed protective environment for easy observation of the newborn.

Air circulation system

keep the air circulation and temperature uniform in the box.

Heating system

Convection heating technology ensures temperature stability and avoids overcooling or overheating.

Incubator chassis

Includes closed transparent cover, air circulation system and heating system:

Infant Incubator Features

Helps newborns maintain body temperature, high humidity environment reduces water loss, protects baby's skin and respiratory tract, especially for low birth weight and preterm babies.

The incubator is equipped with a high-efficiency air filtration system to provide a clean and sterile environment to prevent infection and control the spread of pathogens.

Newborns, especially preterm infants, have a weak ability to regulate their body temperature, and thermostatic culture is effective in avoiding hypothermia or hyperthermia.

Preventing complications of hypothermia: avoiding metabolic disorders and brain damage caused by hypothermia in newborns.

Infusion: Provides intravenous nutrition and medication for newborns who are unable to feed themselves or who require specialized treatment.

Oxygen Delivery: to provide stable oxygen support and improve oxygenation in newborns with respiratory distress syndrome (RDS) or other respiratory conditions.

Resuscitation operation: Through the operation window on the transparent cover, medical personnel can quickly carry out first aid measures.

Real-time recording of the newborn's heart rate, respiration, temperature and other key indicators to provide a basis for treatment decisions.

Blue Light Therapy: treats jaundice in newborns by breaking down bilirubin in the body with light of a specific wavelength.

Humidification Mode: Provides an ultra-high humidity environment for very preterm infants to prevent excessive evaporation of body fluids.

Data Storage And Remote Monitoring: Some devices support recording of nursing data or remote real-time viewing, making it easy for healthcare professionals and parents to track the recovery progress of newborns.

NICU (Neonatal Intensive Care Unit), General Delivery Room, Long Distance Transportation of Critically Ill Children

Infant Radiant Warmer

The Infant Radiant Warming Table is a medical device designed specifically for newborns that utilizes infrared radiation devices to provide continuous warmth support to infants. It is equipped with a digital skin temperature sensor and a far-infrared temperature detector for real-time monitoring of the newborn’s body surface temperature and bed surface temperature during care to ensure that the temperature is maintained in a safe range. The device is widely used in labor and delivery wards, neonatal units and NICUs to provide open warmth support to newborns, and is particularly suitable for short-term care and resuscitation.

component

The Baby Radiant Warming Table consists of the following nine main parts:

LED lighting

Provides clear illumination.

Radiant Head

Equipped with an infrared heater that provides a constant source of radiant heat to the baby and ensures that the heat is evenly distributed.

Controller

Adjustment of parameters via digital display.

Crib

The bed is soft and comfortable with an adjustable tilt angle to facilitate newborn care operations or specific medical needs.

Rack

Stable support for the whole equipment, can be moved flexibly, easy to use in different areas.

Skin Temperature Sensor

Real-time monitoring of baby's skin temperature

Infusion Stand

Used to hold infusion equipment in place.

Jaundice Treatment Device

(Optional)

Functions of the Baby Radiant Warming Table

The Infant Radiant Warming Table is an important piece of neonatal medical equipment designed to provide open care, resuscitation support, and thermoregulation for newborns, preterm infants, critically ill infants, and frail infants.

Open care support

Open care support

Open Design: The open design facilitates healthcare workers to perform various nursing operations, such as infusion, medication change and intubation.
Wide Field Of Vision:healthcare workers can observe the condition of newborns at any time, and quickly detect and deal with abnormalities.

Emergency rescue function

Emergency rescue function

Instant Warming: the infrared radiation device provides heat quickly to maintain a stable body temperature for newborns during resuscitation.
Flexible Mobility:the rack with wheels facilitates the rapid transfer of the equipment to different wards or operating rooms during resuscitation.

Temperature Regulation & Monitoring

Temperature Regulation & Monitoring

Infrared Radiation Technology:Provides even, continuous warmth to newborns through an infrared radiation device to help immature newborns maintain a normal body temperature.
Servo Temperature Control System:combining skin temperature sensor and far infrared temperature detector, adjusting the heat output in real time according to the newborn's body temperature, avoiding too low or too high temperature.

APGAR Timer & Alarm Systems

APGAR Timer & Alarm Systems

Integrated APGAR Timer: to assist in newborn assessment.
Alarm systems: for high/low temperature, sensor failure, or power loss.

Special function extensions

Special function extensions

Jaundice treatment (optional), multi-parameter monitoring, radiographic support, oxygen cylinder, suction, resuscitator, etc.

Short-term care and stabilization support

Short-term care and stabilization support

Post-Operative Care:temperature maintenance and care of newborns suitable for a short period of time after surgery to ensure their gradual recovery in a stable environment.

Infant Phototherapy Unit

Infant Phototherapy Unit, also known as Blue Light Therapy Instrument, utilizes short-wave blue light to irradiate the skin surface of newborns to promote bilirubin metabolism and accelerate the metabolism and discharge of bilirubin, thereby treating neonatal jaundice.

categorization

mobile version

Mobile jaundice treatment instrument light box angle and height can be adjusted, casters can be fixed, can be used alone, can also be used with infant incubatorThe Infant Radiant Warming Table is a medical device designed specifically for newborns that utilizes infrared radiation devices to provide continuous warmth support to infants. It is equipped with a digital skin temperature sensor and a far-infrared temperature detector for real-time monitoring of the newborn’s body surface temperature and bed surface temperature during care to ensure that the temperature is maintained in a safe range. The device is widely used in labor and delivery wards, neonatal units and NICUs to provide open warmth support to newborns, and is particularly suitable for short-term care and resuscitation.

retainer

Divided into matching incubator models and treatment bed models, matching incubator models have suction cups at the bottom, can be adsorbed in the upper part of the incubator to use, treatment bed models can be used as a separate treatment.

Our Infant Incubator and Infant Radiant Warming Table

CNME010702

Infant Incubator

CNME010712

Infant Incubator

CNME0107A1

Infant Incubator

CNME010716

Infant Radiant Warming Table

CNME010724

Infant Radiant Warming Table

CNME0107A2

Infant Radiant Warming Table

CNME010728

Infant Phototherapy Unit

CNME010744

Infant Phototherapy Unit

CNME0107A3

Infant Phototherapy Unit